Home » Multimeter Voltmeter Thermometer AC DC Voltage Resistance Frequency Triode Diode Dual-slope Integrating A/D Converter System » Multimeter Voltmeter Thermometer AC DC Voltage Resistance Frequency Triode Diode Dual-slope Integrating A/D Converter System

Multimeter Voltmeter Thermometer AC DC Voltage Resistance Frequency Triode Diode Dual-slope integrating A/D Converter System

Multimeter Voltmeter Thermometer AC DC Voltage Resistance Frequency Triode Diode Dual-slope integrating A/D Converter System
  • SellerIdeal Concept Store
  • Price ofUS $44.90 piece
  • Your PriceUS $33.68piece
  • ShippingFree Shipping
  • You SavesUS $11.22piece25% off
  • Ratings4 (3427)

Product Details

Buying for a Multimeter Voltmeter Thermometer AC DC Voltage Resistance Frequency Triode Diode Dual-slope integrating A/D Converter System with cheapest price? Read about features, types, and other must-know topics in our Multimeter Voltmeter Thermometer AC DC Voltage Resistance Frequency Triode Diode Dual-slope integrating A/D Converter System buying guide to make an informed choice. Order good Multimeter Voltmeter Thermometer AC DC Voltage Resistance Frequency Triode Diode Dual-slope integrating A/D Converter System Look for the Multimeter Voltmeter Thermometer AC DC Voltage Resistance Frequency Triode Diode Dual-slope integrating A/D Converter System package that is good for you. Make a price comparison, discount promo, or free shipping before buying.

 
FEATURES:
  • Auto-off and buzzer
  • Low battery indication  
  • Automatic negative polarity indication
  • Manual and automatic ranging
  • Full overload protection
  • Functions: DCV, ACV, DCA, ACA, Resistance, Capacitance, Frequency, Temperature, Duty Cycle Measurement, Triode, Diode and Continuity Test
 
 
 
 
Complete set includes:
  • 1 x Digital Multimeter
  • 1 x Test Leads
  • 1 x K-Type Thermocouple Wire
  • 2 x 1.5V AAA batteries (included)
  • 1 x Non-slip Rubber Protection Cover
  • English Intsruction Manual
 
 
 
 
 
SPECIFICATIONS:
  • Display: 3 ¾ digit Large LCD with a max readings of 3999
  • Measuring method: Dual-slope integrating A/D Converter System
  • Sampling Rate: approx. 3 Times / Second
  • Over range indication: "OL" display
  • Operating Temperature: 0 ~ 40°C; Operating Humidity: <80% RH
  • Storage Temperature: -10 ~ 50°C; Storage Humidity: <80% RH
  • Power: 2 x 1.5V AAA batteries (included)
  • Dimensions: 185(L) x 93(W) x 35(H) mm
  • Weight: approx. 290g (including battery)
 
 

Technical Specification:

Accuracy is ±(percentage of reading + number of digit) at (23±5) °C, <75% RH.

 

DC Voltage

Range
Accuracy
Resolution
400mV
±(0.5%+4d)
0.1mV
4V
1mV
40V
10mV
400V
100mV
1000V
±(1.0%+4d)
1V

Input impedance: 400 mV range: more than 40MΩ ; other range: 10MΩ
Overload protection: 1000 V DC or 750V AC peak value

 

AC Voltage (only 400mV range has manual range)

Range
Accuracy
Resolution
400mV
±(1.5%+6d)
0.1mV
4V
±(0.8%+6d)
1mV
40V
10mV
400V
100mV
750V
±(1.0%+6d)
1V

Input impedance: 400 mV range: more than 40 MΩ ; other range: 10 MΩ
Frequency response: 750 v range: 40-100 Hz ; other range: 40-400 Hz
Overload protection: 1000 V DC / 750 V AC peak value

 

DCA

Range
Accuracy
Resolution
400uA
±(1.0%+5d)
0.1uA
4000uA
1uA
40mA
10uA
400mA
100uA
4A
1mA
20A
±(2.0%+5d)
10mA

Max. Measuring volt drop: 400mV under mA range, 200mV under A range.
Max. input current: 20A (less than 10 sec)
Overload protection: 0.5/250V fuse, 15A/250V fuse

 

ACA

Range
Accuracy
Resolution
400uA
±(1.5%+5d)
0.1uA
4000uA
1uA
40mA
10uA
400mA
100uA
4A
1mA
20A
±(2.0%+10d)
10mA

Max. Measuring volt drop: 400mV under mA range, 200mV under A range.
Max. input current: 20A (less than 10 sec)
Overload protection: 0.5/250V fuse, 15A/250V fuse
Frequency response: (40~100)Hz under 20A range, (40~400) Hz at other range.

 

Resistance

Range
Accuracy
Resolution
400Ω
±(0.8%+5d)
0.1Ω
4kΩ
±(0.8%+2d)
40kΩ
10Ω
400kΩ
100Ω
4MΩ
1kΩ
40MΩ
±(1.2%+5d)
10kΩ

Overload protection: 250V DC/AC Peak Value
Open circuit voltage: 400 mV

 

Capacitance

Range
Accuracy
Resolution
4nF
±(0.5%+20d)
1pF
40nF
±(3.5%+8d)
10pF
400nF
100pF
4uF
1nF
40uF
10nF
200uF
±(5.0%+8d)
100nF

Overload protection: 250V DC/AC Peak Value

 

Frequency

Range
Accuracy
Resolution
10Hz
±(0.5%+4d)
0.01Hz
100Hz
0.1Hz
1000Hz
0.1Hz
10kHz
1Hz
100kHz
10Hz
1MHz
100Hz
30MHz
1kHz

INPUT SENSOR: 0.7V

Overload protection: 250V DC/AC Peak Value

 

Diode and Continuity Test

Range
Description
Test Condition
Diode
 
Display read approx.forward voltage of diode
Forward DC Current approx 0.5mA Reversed voltage approx. 1.5V
Buzzer
Buzzer sounds if resistance between terminals V/Ω and COM is less than (50± 10) Ω
Open circuit voltage:0.5V

Overload Protection: 250 V DC/AC peak value
Warning: Do not input Voltage at the range for safety

 

hFE

Range
Description
Test Condition
NPN or PNP
0 ~ 1000
Basic Current is Approx. 15 µA. Vce is approx. 4.5V

 

Temperature

Range
Description
Test Condition
-40 - 1000 °C
< 400 °C ± (0.8% + 4)
≥400 °C ± (1.5% + 15)
1 °C

Thermocouple: K Type
Warning: Do not input any voltage at this range

 

 

 

 

 

3

 

 

 

3-Ideal-Concept-Multimeter-VC-97-Set

 

 

2-Ideal-Concept-Multimeter-VC-97-Application

 

 

4-Ideal-Concept-Multimeter-VC-97-parts

 

 

5-Ideal-Concept-Multimeter-VC-97-Dimension

 

 

6-Ideal-Concept-Multimeter-VC-97-LCD

 

 

7-Ideal-Concept-Multimeter-VC-97-Switch

 

8-Ideal-Concept-Multimeter-VC-97-Input-Jack

 

 

9-Ideal-Concept-Multimeter-VC-97-Connect

 

 

 

10-Ideal-Concept-Multimeter-VC-97-Stand

 

 

 

 

terms of sale

policy 1policy_2policy_3policy_4policy_5policy_6policy_7

Feedback
we would greatly appreciate it if you could leave us some feedback when you receive your item/items. we do our very best to provide the best service we possibly can but if for any reason you are unhappy with anything please get in touch before leaving a negative response and we will do our best to your issue resolved.

THANKYOU FOR CHOOSING TO SHOP WITH US

Recent Search